Model Number |
CWDM Transmission System |
u Big capacity
When path transmission rate is 2.5Gbit/s with single-mode fiber, total capacity is 20Gbit/s with 8-wavelength equipment. When path transmission rate is 10Gbit/s with zero water peak fiber, total capacity is 320Gbit/s with 32-wavelength equipment.
u Flexible networking
It can construct with point-to-point, linking, ring, and diplex transmission with one fiber, point-to-multiple points, and etc. network configuration.
u Flexible and transparent access at various rates and for various services
It provides various rate and various service interfaces that can realize the connection with Ethernets, PDH, SDH, optical fiber paths and etc.
u Multiple transmission range
The transmission range is 30km, 50km, 80km and 100km without regenerator.
u Good expandability:
4-wavelength, 5-wavelength, 6-wavelength, 7-wavelength, 8-wavelength and 9-wavelength (include 1310 wavelength)
u 1+1 optical multiplexing section protection function
Optical path switching time is ≤30ms, which guarantees the safety and reliability of the line.
u 1+1 hot stand-by redundant power supply
u Open architecture
It supports access via client sides of various manufactures equipment, as well as interconnection and intercommunication with many manufactures’ equipment.
u Transmission via regenerator
When the transmission range exceeds 80km, regenerator can be used to preamplifier, reshape and refit a time at various rates.
u The optical add and drop multiplex (OADM) function, able to add or drop at various rates.
u Flexible network management configuration and management style
It adopts SNMP-based graphical interface and supports management via in band or out of band. The network management system adopts an embedded operating system and has a real-time monitoring and controlling function. The form of management is flexible and varied, and graphical user interface is friendly.
u System specifications
|
System parameter
|
Technical date
|
|
Maximum capacity
|
4-wavelength (10G), 8-wavelength (20G), 32-wavelength (320G,zero water peak fiber)
|
|
Wavelength range
|
In conformity with the ITU-I G..694.2 standard
|
|
Access service type
|
PDH. ATM
STM-1/STM-4/STM-16/STM-64
OC-3/OC-12/OC-32/ OC-48
Ethernet 10/100BaseT.GE
FICON/ESCON/FIBER Channel
|
|
Transmission mode in the optical interface
|
Adopts the 2R transmission mode, with each path supporting transparent transmission at a rate below 1.25Gbits;
Adopts the 3R transmission mode, with each path able to be set to 155Mbit/s, 622Mbit/s, 1.25Gbit/s or 2.5Gbit/s.
|
|
Topological structures of physical networks
|
Point-to-point, point-to-multiple points, linking, ring, diplex transmission with one fiber.
|
|
Optical fiber type
|
G.652 G.653 G.655
|
|
Network management mode
|
CLI, TELNET, SNMP, WEB
|
|
Mechanical parameter
|
Dimensions
|
19-inch 6U HCW-1000 chassis; 266(H)X250(D)X482(W)(mm)
19-inch 1U HCW-1000 chassis; 44(H)X280(D)X440(W)(mm)
|
|
Weight
|
15kg per shelf fully loaded
|
|
Operation Environment
|
Operating temperature
|
-10℃~60℃
|
|
Relative humidity
|
5%~95%, no condensing
|
|
Store Environment
|
Ambient temperature
|
-40℃~80℃
|
|
Relative humidity
|
5%~95%, no condensing
|
|
Power supply
|
220VAC, 50Hz; -48VDC(optional)
|
|
Power consumption
|
≤55W
|
u Optical interface data
|
Items
|
Description
|
|
Central wavelength
|
1470nm, 1490nm, 1510nm, 1530nm, 1550nm, 1570nm, 1590nm, 1610nm(1310nm among options), support DWDM path upgrade.
|
|
Wavelength spacing
|
CWDM: 20nm/DWDM: 0.8nm
|
|
Optical path width
|
±6.5nm
|
|
Temperature drift of the central wavelength
|
0.08nm~0.1nm/℃
|
u Characteristics of the external interfaces
|
Items
|
Description
|
|
Interface
|
Line-end
|
SC or FC interface, provide optical fiber converters, fiber jumpers, etc.
|
|
Client-end
|
SC interface (standard), FC, LC, etc. interface (optional)
|
|
Interface standard
|
IEEE802.3ae, G.957, etc
|
|
Wavelength range at the client end
|
Multiple-mode: 850nm; single-mode with double fibers: 1200nm-1610nm; diplex transmission with single-mode and fiber:1310nm/1550nm
|
|
Optical fiber jumper
|
G.652 single-mode fibers (multiple-mode fiber can be used at client-end)
|
u Characteristics of the network management interface
|
Items
|
Description
|
|
Network management interface
|
10M Ethernet RJ45 interface; DB9 R232 serial port
|
|
Remote optical interface
|
1310nm wavelength path (SC)
|
Applicable Conditions
u It’s suitable for the high-speed interconnection and transparent transmission in trunk networks and border networks, as well as access networks, converge node in broadband optical MANS.
u It’s suitable for point-to-point, point-to-multiple points, linking, ring, and diplex transmission with one fiber and etc.
u It provides flexible access at various data types and various rates, and problem can be solved to optical fiber resource shortage.
Strong and flexible network management configuration and management mode:
u Network management based on the SNMP protocol, as well as the use of the graphic interface and command lines. Available with four main functions of the network management as defined in the ISO/IEC7498-4 document by the International Standardization Organization.
u Multiple network management styles:
² Console-based local management
² Telnet management
² Web-based WebRiver management
² SNMP-based visual GUI graphical interface management
u Topological graphical management
|